Permit: T99CM01771

Parcel: 118050330

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/23/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
10/16/2001 BUILDING - FINAL Denied 1) POST ADDRESS ON STRUCTURE
09/25/2001 BUILDING - FINAL Denied 1) PROVIDE DOUBLE WALL FLUE AT WATER HEATER 2) BLOCK CONDENSATION LINE AT ROOF 3) WILL REFEE FOR NEXT INSPECTION
08/17/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) CONDENSTATION LINE NOT INSTALLED CORRECT, PROVIDE VENT PIPE AFTER P TRAP DRAIN INTO VTR WITH SAN T BUSHING 2) INSTALL DOUBLE WALL FLUE PIPE AT HOT WATER OR PROVIDE 6" CLEARANCE FROM COMBUSTIBLE MATERIAL
04/12/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/COMBUSTION RELIEF FOR HOT WATER NOT INSTALLED CORRECT AND NOT SIZED ACCORDING TO PLAN, IDENTIFY ALL CIRCUIT BREAKERS AT PANEL, POINT ABS ON ROOF,SEAL PENETRATIONS AT DOOR AND SLIDER FROM INFILTRATION, PROVIDE CLEAN OUT FOR WASHER/KITCHEN CLEAN OUT NEEDS TO BE ACCESSIBLE, ADJUST BOMBER DOOR TO SELF CLOSE INSTALL HINGES, PROVIDE BOND WIRES FOR GAS/WATER PIPES, REMOVE OUTLETS UNDER COUNTER TOP PROVIDE PROTECTIVE COVER, PROVIDE 221/2" X 30" ATTIC ACCESS