Inspection History Details
Inspection Status: Correction Required
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/1999 | ROOF NAILING | Correction Required | ADDTL COMMS - OK TO COVER ROOF DECK 1. 4 LINE OF NAILING MISSING. 2. CHANGE OUT 2X6 HEADERS TO 2X8 ADD TRIM STUDS-CRIPPLES. |