Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T99CM01546

Parcel: 114511020


Addresses:

9281 E NORTHVIEW CT

Inspection Status: Correction Required

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/27/1999 BUILDING - FINAL Correction Required ADDTL COMMS - SEE ITEMS 4,5,7,9
10/27/1999 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*
10/25/1999 BUILDING - FINAL Correction Required ADDTL COMMS - 1. WEATHER PROOF COVER ON GFCI AT AC. 2. ADDRESS NUMBERS ARE MISSING. 3. ENTRY LIGHT FIXTURE IS NOT IN. 4. GRADING INCOMPLETE. REMOVE TAPE AT DOUBLE WALL FLUE AT HOT WATER HEATER. 5. FEMALE PVC FITTING PROHIBITED AT AIR HANDLER. 6. CAULK FIREPLACE. GAS AND HOLD-OPEN NEEDED ON DAMPER. 7. RECEPTACLE NEEDED 24 FROM END OF KITCHEN COUNTER. 8. CONDENSATE LINE CRIMPED UNDER VANITY. 9. 1 TO COMBUSTIBLES AT HALL FURNACE FLUE.
10/25/1999 BUILDING - FINAL Denied IVRS - Inspection 0999*