Inspection Status: Correction Required
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - SEE ITEMS 4,5,7,9 |
| 10/27/1999 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000* |
| 10/25/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - 1. WEATHER PROOF COVER ON GFCI AT AC. 2. ADDRESS NUMBERS ARE MISSING. 3. ENTRY LIGHT FIXTURE IS NOT IN. 4. GRADING INCOMPLETE. REMOVE TAPE AT DOUBLE WALL FLUE AT HOT WATER HEATER. 5. FEMALE PVC FITTING PROHIBITED AT AIR HANDLER. 6. CAULK FIREPLACE. GAS AND HOLD-OPEN NEEDED ON DAMPER. 7. RECEPTACLE NEEDED 24 FROM END OF KITCHEN COUNTER. 8. CONDENSATE LINE CRIMPED UNDER VANITY. 9. 1 TO COMBUSTIBLES AT HALL FURNACE FLUE. |
| 10/25/1999 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* |