Inspection Status: Correction Required
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/08/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - OKAY TO CLEAR UTS. GAS TAG ON RISER. CERTS. OKAY. |
| 10/07/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - CLEANOUT NEED TO BE CUT TO GROUND LEVEL, FLUE VENTS NEED CAP, PAN MISSING IN CHASE, EXTEND GAS LINE OUT OF FURNACE, PATCH DRYWALL ABOVE FURNACE, NEED CLEANOUT CAP ON EAST BATHROOM, REPAIR STUCCO AT FIREPLACE, NEED CAP ON RANGE VENT. NOTE - ATTIC FURNACE OK |
| 10/07/1999 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 10/06/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - REPAIR FIRE CEILING IN GAR |
| 10/06/1999 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0185* |
| 10/04/1999 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 09/29/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - 1. 25 AMP MAX. BREAKER AT AC. 2. 1 HRS FIREWALL NOT SEALED AT FREON LINE AT FURNACE. 3. PAINT EXPOSED PVC AT IRRIGATION. 4. NEED WATER BOND CONNECTED IN PANEL. WHY IS PANEL LISTED NON-METALIC WATER PIPING. 5. RAIN CAP MISSING OFF FLUES AND RANGE HOOD VENTS. 6. FAN NOT WORKING AT LAUNDRY AND MASTER BATH W.CLOSET. 7. SUPPLY PAPERWORK ON HEARTH REQUIREMENTS. 8. C/O NOT CAPPED EASTSIDE OF HOUSE. |
| 09/29/1999 |
BUILDING - FINAL |
|
Denied |
DENIED |