Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/01/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - MARK YOU LOT OR ADDRESS NUMBERS ON EACH HOUSE- NOT ON CURB, CURB NUMBERS COVERED WITH DIRT OR EARASED BY TRAFFIC DRIVE CUT NAIL IN SHORT PLATE OF SHORT PARTITION WALL ON NORTH (RIGHT) SIDE OF HOUSE. |
| 05/26/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 05/20/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. PROVIDE SOLID FLOOR FROM ACCESS DOR MIN 24 WIDE WITH MIN 30 DEEP PLATFORM IN FRONT OF FIRE BOX UMC 908. 2. REMOVE ROOFING UNDER LAYMENT FROM AROUND FURNACE DUCTING. 4. FIRE BLOCKING MISSING AT LIVING ROOM COLUMN. 6. FHA STRAPS AT SHEAR WALL MIN 2-8A PER SIDE EACH STRAP. (NOT 1/8 TCK SCREWS). 8. NO SRU PROVIDED AT FURNACE. SHEET 7 ITEM 8 PER PLAN. STOPPED INSPECTION NOTE: GABLE END TOP CORD OVER NOTCHED 25% MAX NEED REPAIR FROM TRUSS MANUFACTURER. |
| 05/20/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |