Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/04/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - NOTE: CORRECT TRUSS (GABLE) AT FRAMING INSPECTION. |
| 06/02/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. MISSING SHEAR AT FRONT. 2. NO SUPPORT AT GABLE END TRUSS AT GARAGE. 3. DRIVE ROOF FASTENERS FLUSH |
| 06/02/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |