Permit: T99CM01371

Parcel: 103102280

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/04/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - GABLE VENT NOT INSTALLED AT THIS TIME. INTERIOR NON BEARING TRANSFERS AND SHEAR WALL INTERSECTION INCOMPLETE OR WRONG CORRECT BEFORE LOADING ROOF. DETAILS 14/A8 13/A8 AND 5/A8.
05/03/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. BOLT FRONT ENTRY (BEARING) PLATE. 2. NAIL SHEAR AT ROOF 8D AT 6 O.C. 3. INSTALL VENTS AT BACK OF HOUSE. 4. BIRD BLOCKS NOT NAILED AT ENTRY.
05/03/1999 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*