Inspection Status: Correction Required
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/03/1999 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - 1. MISSED 4 RUN NAILS AT ROOF DECK SOUTHE OF H2O SERV LINE TO TOP PLATE. 2. AT NEXT INSPECTION MISSING APPROX SIX TRUSS GUSSET PLATE 2 IN GARAGE NOT MARKED ON FLR ALL OTHERS MARKED IN BLUE ON FLR. |
| 04/30/1999 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - HOUSE ONLY |
| 04/30/1999 |
ROOF NAILING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 04/29/1999 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - 1. MISSING NAILING AT ROOF DECK SEE BLUE MARKS. 2. MISSING NAILING AT EXT. SHEAR WALLS, NAIL ALL HORIZ/VERT EDGES (H.D. TO H.D. ONLY). 3. CHECK H.D. NAILING IN REAR TWO ROWS OF NAILS PER H.D. SOME ROWS MISSED STUDS. 4. BLOCK FROM BELOW AND NAIL, MARKED ON ROOF ONE CORNER OF PLY |
| 04/29/1999 |
ROOF NAILING |
|
Denied |
DENIED |