Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T99CM01092
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/14/1999 | FRAMING | Correction Required | ADDTL COMMS - NOTE: BLOCK BACK SIDE OF FURN DUCTS GARAGE THERES NO WAY TO HANG ROCK AT THAT SPACE WITHOUT BACKING. 2. AT FINAL NEED SOME TYPE OF CONNECTION AT 6X12 BEAM TO 6X6 POST OR 4X12 BEAM REAR PORCH NOTHING ON PLAN. | |
05/11/1999 | FRAMING | Correction Required | ADDTL COMMS - 1. BLOCK AROUND DUCT WORK AT GARAGE. 2. PROTECT CONDENSATE LINE FROM SHEET ROCK NAILS. 3. FIRE PLACE METAL STRIP HEARTH PROTECTION NOT INSTALLED. | |
05/11/1999 | FRAMING | Not ready for Inspection | NOT READY FOR INSPECTION | |
05/08/1999 | FRAMING | Correction Required | ADDTL COMMS - 1. FIRE BLOCK ENTRY WAY AT HALLWAY AND KITCHEN ENTRY. 3. DOUBLE STUDS AT ALL GIRDER TRUSS (THROGHOUT). 4. PAPER AGAINST FLUE AND SHEATHING 1 MINIMUM. 5. FURR DOWN FRAMING FOR DUCT WORK IN GARAGE 26 GA. SHEET METAL TO PENETRATE GARAGE FIRE RATED WALL. 6. COULDNT LOCATE PLANS AND PERMIT. 7. STOPPED INSPECTION. | |
05/08/1999 | FRAMING | Not ready for Inspection | NOT READY FOR INSPECTION |