Permit: T99CM01092

Parcel: 128102520

Inspection Status: Correction Required

Inspection History: FRAMING

Permit Number - T99CM01092

Inspection Description - FRAMING

Inspection Status - Correction Required

Date Description Inspector Results Comments
05/14/1999 FRAMING Correction Required ADDTL COMMS - NOTE: BLOCK BACK SIDE OF FURN DUCTS GARAGE THERES NO WAY TO HANG ROCK AT THAT SPACE WITHOUT BACKING. 2. AT FINAL NEED SOME TYPE OF CONNECTION AT 6X12 BEAM TO 6X6 POST OR 4X12 BEAM REAR PORCH NOTHING ON PLAN.
05/11/1999 FRAMING Correction Required ADDTL COMMS - 1. BLOCK AROUND DUCT WORK AT GARAGE. 2. PROTECT CONDENSATE LINE FROM SHEET ROCK NAILS. 3. FIRE PLACE METAL STRIP HEARTH PROTECTION NOT INSTALLED.
05/11/1999 FRAMING Not ready for Inspection NOT READY FOR INSPECTION
05/08/1999 FRAMING Correction Required ADDTL COMMS - 1. FIRE BLOCK ENTRY WAY AT HALLWAY AND KITCHEN ENTRY. 3. DOUBLE STUDS AT ALL GIRDER TRUSS (THROGHOUT). 4. PAPER AGAINST FLUE AND SHEATHING 1 MINIMUM. 5. FURR DOWN FRAMING FOR DUCT WORK IN GARAGE 26 GA. SHEET METAL TO PENETRATE GARAGE FIRE RATED WALL. 6. COULDNT LOCATE PLANS AND PERMIT. 7. STOPPED INSPECTION.
05/08/1999 FRAMING Not ready for Inspection NOT READY FOR INSPECTION