Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T99CM01067
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/02/2001 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* OK FOR C OF O PENDING ANY OTHER INSP. | |
02/27/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* 1) CLEAN OUTS TO BE INSTALLED ON VERTICAL PIPING 2) PLEASE CAP OFF ALL OPEN PIPES IN THE ATTIC OR TRACE BACK TO ORIGINAL DISCONNECT AND CAP OFF THERE 3) BRACE AND SUPPORT HORIZONTAL PIPING TO TABLE 3-1 4) USE APPROVED FITTINGS FOR INTERMINGLING OF MATERIALS 5) CORRECT BACK PITCH AT WATER HEATER T AND P RELIEF DRAIN |