Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T99CM01067

Parcel: 117140940


Addresses:

385 S STONE AV 01


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T99CM01067

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/02/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000* OK FOR C OF O PENDING ANY OTHER INSP.
02/27/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) CLEAN OUTS TO BE INSTALLED ON VERTICAL PIPING 2) PLEASE CAP OFF ALL OPEN PIPES IN THE ATTIC OR TRACE BACK TO ORIGINAL DISCONNECT AND CAP OFF THERE 3) BRACE AND SUPPORT HORIZONTAL PIPING TO TABLE 3-1 4) USE APPROVED FITTINGS FOR INTERMINGLING OF MATERIALS 5) CORRECT BACK PITCH AT WATER HEATER T AND P RELIEF DRAIN