Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T99CM00707

Parcel: 125071230


Addresses:

625 N TREAT AV

Inspection Status: Partial Approval

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/13/2000 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*/1. TEMPORARY STAIR HAND RAIL INSTALLED CALL FOR FINAL INSPECTION WHEN PERMANENT HANDRAIL IS INSTALLED. BE SURE TO INSTALL AT 36" + 2" ABOVE STAIR NOSE. INSULATION CERT TURNED IN.
10/09/2000 BUILDING - FINAL Denied 1. INSTALL ADDRESS IN 3" HIGH MINIMUM NUBERS. 2. TRIM C/O TO GRADE. 3. PORCH LIGHTS/COVERS MISSING. 4. OUTSIDE ELECT OUTLET MUST BE GFCI 5. BASEMENT MECH REQUIRES COMBUSTION AIR. 6. SUPPORT FURNACE (NORTH) GAS LINE. 7. W/H VENT NOT COMPLETE OR TAPED. 8. CLEAN OUT CAPS MUST HAVE THREADED CAPS/PLUGS--NOT JIM CAPS. 9. PROTECT N.M.C. BY CLEAN OUTS BASEMENT. 10. LABLE SVC PANEL AND PLUG K. O. S. 11. 4TH C/B RT 20 AMP WITH 14 GA WIRE. 12. G E PANEL CANNOT USE SQUARE D BREAKERS SUB PANEL B. 13. STAIR HAND RAIL MISSING. 14. BARE BULB FIXTURE NOT ALLOWED IN CLOSETS. 15. 4 PRONG PLUG REQ. ON DRYER.