Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/17/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. SEE PREVIOUS INSPECTION DELETE ITEMS 1-6. |
| 03/15/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. BLKS MISSING FOR SHEAR WALL #2. 2. FRAMING MISSING UNDER COMMON TRUSSES AT BDRM. DEN OPT. 3. 2X4 TOP CORD OF TRUSSES NOTCHED FOR LOOK-OUTS NEED TRUSS MANUFACTUERS APPROVAL. 4. GABLE BRACES NOT NAILED DOWN FROM TOP. 5. VALLEY RAFTERS NOT NAILED. 6. NAILING MISSING ABOVE GARAGE. 7. INT SHEAR AT END OF GARAGE NOT NAILED IN PLACES. |
| 03/15/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |