Permit: T99CM00698

Parcel: 137279630

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/17/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. SEE PREVIOUS INSPECTION DELETE ITEMS 1-6.
03/15/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. BLKS MISSING FOR SHEAR WALL #2. 2. FRAMING MISSING UNDER COMMON TRUSSES AT BDRM. DEN OPT. 3. 2X4 TOP CORD OF TRUSSES NOTCHED FOR LOOK-OUTS NEED TRUSS MANUFACTUERS APPROVAL. 4. GABLE BRACES NOT NAILED DOWN FROM TOP. 5. VALLEY RAFTERS NOT NAILED. 6. NAILING MISSING ABOVE GARAGE. 7. INT SHEAR AT END OF GARAGE NOT NAILED IN PLACES.
03/15/1999 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*