Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T99CM00670
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/18/1999 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - OKAY TO COVER 1. NEED MORE NAILS IN HEADER FRONT BEDROOM WEST WALL. 2. SD4/7 SHEAR TRANSFER NEED DETAIL FOR THIS SITUATION FOR INTERMEDIATE INSPECTION. 3. NEED HANGERS FOR IJIS ANGLE LEDGER FRONT BEDROOM. 4. SEE ROOF FRAMING PLAN CALLS FOR MULTIPLE STUDS UNDER BEAM FRONT ENTRY YOU HAVE ONE BEARING STUD. 5. REAR PORCH DETAIL CALLS FOR 4X4 POST B EDC 44 HARDWARE. |