Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/14/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - APPROVED - ACCESS WILL BE CUT THROUGH MASONRY TO OUTSIDE. |
| 03/31/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED - STOPPED INSPECTION-NOT COMPLETE ENOUGH TO INSPECT. 1. NO PRIOR INSPECTION REPORT ON SITE. ALL PRIOR REPORTS MUST BE AVAILABLE. 2. TRUSSES MUST BE CLIPPED TO TOP PLATE ON MASONRY WALL-NOT FURRING. 3. TRUSSES REQUIRE WEB STRINGERS - SEE TRUSS DRAWINGS. 4. TRUSSES MUST BE CLIPPED TO INTERIOR BEARING WALL. 5. BACK GROUT FLOOR PENETRATION UNDER TUB. 6. PROVIDE 14 X 14 ACCESS PANEL TO JACUZZI PUMP AND ELECTRIC OUTLET. 7. PROVIDE 22 X 30 ATTIC ACCESS. 8. 1/2 WATER LINE CANNOT SUPPLY MORE THAN 2 FIXTURES. 9. COULD NOT LOCATE MECHANICAL PLAN. |
| 03/31/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0950* |
| 03/09/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED - REVISE PLAN TO SHOW EXISTING. NOT TO PLAN. |
| 03/09/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |