Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T99CM00406
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/02/1999 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - BE ADVISED: 1. YOU ARE REQUIRED TO NUMBER EACH LOT WITH NUMBERS READILY IDENTIFIABLE FROM STREET SIDE. THIS IS A CODE AND CITY ORDINANCE REQUIRMENT. MARK YOUR LOTS. 2. THE PLATFORM SUPPORTING THE WATER HEATER IS NOT PART OF THE REQUIRED 1 HOUR SEPARATION BETWEEN GARAGE AND HOUSE. THE COMMON WALL UNDER THE PLAT FORM WILL REQUIRE 5/8 FIRE X GWB OR 1/2 O.S.B. INSPECTION WILL TAKE PLACE AT INTERMEDIATES. | |
02/26/1999 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. CLIP STUDS WITH HOLD DOWNS TO DOUBLE TOP PLATE. 2. NO LOT NUMBER OR ADDRESS. 3. SHEAR WALL 7 REQUIRES NAILING AT 6 AND 12 FIELD. 4. SHEAR WALL NAILS DRIVEN TOO DEEP RENAIL. 5. PORCH ENTRY COLUMNS REQUIRE PLY WOOD SHEATHING. 6. HOLD DOWN MISSING BY REAR 6040. 7. CLIP REAR WALL TO TRUSS BY PATIO DOOR. 8. SEVERAL AREAS OF ROOF NOT NAILED. | |
02/26/1999 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* |