Permit: T99CM00406

Parcel: 141136980


Addresses:

8910 E LA PALMA DR


Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T99CM00406

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Correction Required

Date Description Inspector Results Comments
03/02/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - BE ADVISED: 1. YOU ARE REQUIRED TO NUMBER EACH LOT WITH NUMBERS READILY IDENTIFIABLE FROM STREET SIDE. THIS IS A CODE AND CITY ORDINANCE REQUIRMENT. MARK YOUR LOTS. 2. THE PLATFORM SUPPORTING THE WATER HEATER IS NOT PART OF THE REQUIRED 1 HOUR SEPARATION BETWEEN GARAGE AND HOUSE. THE COMMON WALL UNDER THE PLAT FORM WILL REQUIRE 5/8 FIRE X GWB OR 1/2 O.S.B. INSPECTION WILL TAKE PLACE AT INTERMEDIATES.
02/26/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. CLIP STUDS WITH HOLD DOWNS TO DOUBLE TOP PLATE. 2. NO LOT NUMBER OR ADDRESS. 3. SHEAR WALL 7 REQUIRES NAILING AT 6 AND 12 FIELD. 4. SHEAR WALL NAILS DRIVEN TOO DEEP RENAIL. 5. PORCH ENTRY COLUMNS REQUIRE PLY WOOD SHEATHING. 6. HOLD DOWN MISSING BY REAR 6040. 7. CLIP REAR WALL TO TRUSS BY PATIO DOOR. 8. SEVERAL AREAS OF ROOF NOT NAILED.
02/26/1999 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*