Permit: T99CM00312

Parcel: 113061640


Addresses:

3232 N OLSEN AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/29/2000 BUILDING - FINAL Approved IVRS - Inspection 0000*
12/27/2000 BUILDING - FINAL Denied 1. ADDRESS 3232 MUST BE ON HOUSE MIN. 3' NUMBERS. 2. CLIP PORCH RAFTERS. 3. DEAD FRONT REQUIRED ON SERVICE PANEL. LABLE ALL CIRCUITS. 4. ANTI SIPHON VALVE REQUIRED ON OUTSIDE HOSE BIB. 5. SHUT OFF VALVE REQUIRED UP STREAM OF UNION WITHIN 36" OR USE LEFT AND RT. HANDED COUPLING. 6. ISOLATED NEUTRAL BAR REQUIRED ON SUB PANEL. 7. 14 GA WIRE CANNOT BE ON 20 AMP BREAKER 15A MAX. 8. BARE BULB FIXTURE NOT ALLOWED IN CLOSET. 9. FIRE PROOF CAULK FIREPLACE PENETRATION.