Inspection History Details
Inspection Status: Correction Required
Inspection History: BUILDING - FINAL
Permit Number - T99CM00252
Inspection Description - BUILDING - FINAL
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2000 | BUILDING - FINAL | Correction Required | ADDTL COMMS - THE RELOCATED COLUMNS AND BEAMS FOR THE BALCONY WERE BUILT AFTER IMMEDIATE INSPECTION WITHOUT FURTHER INSPECTION OR APPROVAL. YOU MUST PROVIDE PROOF OF INSPECTION OR EXPOSE FOOTINGS TO 18 BELOW GRADE AND EXPOSE POST TO GLU-LAM BEAM CONNECTION AND ALL JOIST CONNECTIONS. HAVE REVISED BALCONY MODIFICATION PLAN APPROVED BY CITY OF TUCSON. THE SITE PLAN APPROVED 12-21-99 INDICATES A SETBACK TO THE HOUSE WITHOUT THE BALCONY OF 216 WHICH EXISTS BUT THE TRUE SETBACK FROM THE NORTH IS 118 TO THE BALCONY. YOU MUST PROVIDE A CITY OF TUCSON APPROVED SITE/PLOT PLAN INDICATING SETBACKS AS BUILT. FIREPLACE HEARTH IS NOT CONSTRUCTED PER SUPERIOR FIREPLACE INSTALLATION MANUAL/INSTRUCTIONS. COMBUSTIBLE MATERIAL IS NOT ALLOWED ABOVE THE BOTTOM OF THE UNIT IN FRONT OF THE FIREBOX. | |
04/19/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0935* | |
03/08/2000 | BUILDING - FINAL | Correction Required | ADDTL COMMS - DENIED - NEXT FAILURE THERE WILL BE A RE-INSPECTION FEE. 1. THIS HOUSE NEVER HAD INTERMEDIATE INSPECTIONS APPROVED. PARTIAL APPROVAL WAS GIVEN ON 03-03-99, DUE TO THE HOUSE HAVING AN ADDITIONAL CARPORT ADDED TO THE FRONT WITHOUT APPROVAL. THAT CARPORT SUBSEQUENTLY HAS BEEN MODIFIED TO A PORCH/BALCONY. I FIND NO RECORD OF INSPECTION FOR THAT MODIFICATION. THERE IS A SITE PLAN APPROVED 11-30-99. THERE IS NO FRONT SETBACK LISTED OR CONSTRUCTION DETAIL AVAILABLE FOR THE BALCONY. THE SITE PLAN DATED 11-30-99 DOES NOT MATCH THE OFFICIAL PLOT PLAN DATED 01-20-99. 2. PROVIDE PROOF OF EXTERIOR CLIP INSPECTION APPROVAL. 3. THE FIREPLACE HEARTH IS NOT CONSTRUCTED PER SUPERIOR FIREPLACE INSTALLATION INSTRUCTIONS. COMBUSTIBLE MATERIAL IS NOT ALLOWED ABOVE THE BOTTOM OF THE UNIT IN FRONT OF THE FIRE BOX. 4. STAIRS ARE MISSING HANDRAIL. 5. BALCONY GUARD RAILS ARE TOO LOW. 6. PROVIDE BALCONY CONSTRUCTION PLAN. DETAIL PRESENTLY NOT PROPERLY CLIPPED TO BEAMS. WILL HAVE TO OPEN UP AND INSPECT CONNECTIONS. 7. THERE IS NO DRAIN ON BALCONY. | |
03/08/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999* | |
03/01/2000 | BUILDING - FINAL | Correction Required | ADDTL COMMS - DENIED - NO CHANGE. | |
03/01/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999* | |
02/22/2000 | BUILDING - FINAL | Correction Required | ADDTL COMMS - DENIED - STOPPED INSPECTION. 1. NO ADDRESS NUMBERS. 2. DRYER OUTLET CANNOT HAVE A GRILL. 3. PROVIDE DOCUMENTATION OF COMBUSTIBLES ABOVE THE BOTTOM OF FIREPLACE. 4. REVISE SITE PLANS FOR FRONT PORCH BALCONY. | |
02/22/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999* | |
10/20/1999 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection 0000* |