Permit: T99CM00104

Parcel: 125091470


Addresses:

406 N TREAT AV

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
04/17/2001 ELECTRIC - INTERMEDIATE Approved
11/06/2000 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
OK ROUGH
11/01/2000 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0245*
DID NOT COMPLY WITH NOTES FROM PREVIOUS INSPECTION NEC 336-20 336-18
10/26/2000 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*10/26/00 OK WALLS CEILINGS EXCEPT AS NOTED
PUSH IN PLASTIC BUSHING NOT APPROVED FOR TERM ROMEX INTO BOX. BREAKER PANEL AND STEP LIGHT PVC SLEEVES OR CHASES ABOVE BREAKER PANEL NOT APPROVED METHOD OF CONNECTING ROMEX TO PANEL. USE APPROVED CONNECTORS LISTED FOR PURPOSE
INSTALL GROUND TAILS FOR LIGHT SWITCHES
01/20/2000 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - GUEST HOUSE
01/20/2000 ELECTRIC - INTERMEDIATE Partial Approval PARTIAL APPROVAL