Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/17/2001 | ELECTRIC - INTERMEDIATE | Approved | ||
| 11/06/2000 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* OK ROUGH |
|
| 11/01/2000 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0245* DID NOT COMPLY WITH NOTES FROM PREVIOUS INSPECTION NEC 336-20 336-18 |
|
| 10/26/2000 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*10/26/00 OK WALLS CEILINGS EXCEPT AS NOTED PUSH IN PLASTIC BUSHING NOT APPROVED FOR TERM ROMEX INTO BOX. BREAKER PANEL AND STEP LIGHT PVC SLEEVES OR CHASES ABOVE BREAKER PANEL NOT APPROVED METHOD OF CONNECTING ROMEX TO PANEL. USE APPROVED CONNECTORS LISTED FOR PURPOSE INSTALL GROUND TAILS FOR LIGHT SWITCHES |
|
| 01/20/2000 | ELECTRIC - INTERMEDIATE | Correction Required | ADDTL COMMS - GUEST HOUSE | |
| 01/20/2000 | ELECTRIC - INTERMEDIATE | Partial Approval | PARTIAL APPROVAL |