Inspection History Details
Inspection Status: Correction Required
Inspection History: STEM WALL/RETAINING WALL
Permit Number - T99BU03438
Inspection Description - STEM WALL/RETAINING WALL
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/12/2000 | STEM WALL/RETAINING WALL | Correction Required | ADDTL COMMS - 1. PROVIDE VERTICALS AT NORTH END. 2. LAP BOND BEAMS 40 DIAMETERS (20 FOR #4). 3. EXTEND BOND BEAM STEEL TO THE END OF THE WALL. 4. COMPLETE BOND BEAM AT NORTH END. | |
01/12/2000 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection 0000* | |
01/10/2000 | STEM WALL/RETAINING WALL | Correction Required | ADDTL COMMS - LAY STEM BEFAORE INSPECTION. | |
01/10/2000 | STEM WALL/RETAINING WALL | Denied | DENIED | |
01/05/2000 | STEM WALL/RETAINING WALL | Correction Required | ADDTL COMMS - INDICATE WHAT PLAN YOU ARE USING, THE 1.83OR THE 3.83 RETAINING WALL. BOTH PLANS CALL FOR #5 VERTICALS. PLANS CALL FOR A #5 VERTICAL AT P. LASTERS (THIS MEANS YOU SHOULD DRILL INTO EXISTING FOOTING). STEM WALL NOT BUILT. CALL WHEN CORRECTED. | |
01/05/2000 | STEM WALL/RETAINING WALL | Denied | IVRS - Inspection 0999* | |
12/30/1999 | STEM WALL/RETAINING WALL | Not ready for Inspection | NOT READY FOR INSPECTION |