Inspection Status: Correction Required
Inspection History: STEM WALL/RETAINING WALL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/12/2000 |
STEM WALL/RETAINING WALL |
|
Correction Required |
ADDTL COMMS - 1. CLEAN BOND BEAM STEEL. 2. LAP THE BOND BEAMS 40 DIAMETERS (20 FOR #4). 3. EXTEND BOND BEAM STEEL TO THE END OF THE BOND BEAM. 4. PROVIDE VERTICALS FOR THE PILASTER FENCE. |
| 01/12/2000 |
STEM WALL/RETAINING WALL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 01/10/2000 |
STEM WALL/RETAINING WALL |
|
Not ready for Inspection |
DENIED |
| 12/30/1999 |
STEM WALL/RETAINING WALL |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |