Inspection Status: Correction Required
Inspection History: POOL/SPA FINAL/BARRIER
| Date |
Description |
Inspector |
Results |
Comments |
| 12/14/1999 |
POOL/SPA FINAL/BARRIER |
|
Correction Required |
ADDTL COMMS - CHAINLINK FENCE ON NORTH SIDE OF LOT MUST HAVE SLATS INSTALLED TO PREVENT CLIMBING. INSTALLED SCREEN DOES NOT MEET SLAT REQUIREMENTS. GAP IN CHAINLINK FENCE AT NW CORNER EXCEEDS 4 INCHES AND MUST BE CONSTRUCTED TO PREVENT ENTRY FROM ADJOINING PROPERTY CHAINLINK FENCE. GAPS IN SLATS OF REAR CHAINLINK FENCE MUST BE REPAIRED. GAPS UNDER WROUGHT IRON FENCE CANNOT EXCEED 4. POOL GATES MUST BE SELF LATCHING-MISALIGNED. GAPS UNDER CHAINLINK FENCE EXCEEDS 4 IN PLACES |
| 12/14/1999 |
POOL/SPA FINAL/BARRIER |
|
Denied |
IVRS - Inspection 0999* |