Inspection History Details
Inspection Status: Correction Required
Inspection History: BUILDING - FINAL
Permit Number - T99BU01865
Inspection Description - BUILDING - FINAL
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/12/1999 | BUILDING - FINAL | Correction Required | ADDTL COMMS - NAIL FASCIA TO EVERY RAFTER, COVER PLYWOOD EDGES WITH METAL TRIM, PROVIDE JOIST HANGERS (4) AT SKYLIGHT HEADERS, NAIL THE TWO 2 X 8S AT THE HIP WITH 16D NAILS STAGGERED AT 16 C.C., NAIL THE SLANTED JOIST HANGERS AT THE HIP. CHECK ALL OF THE HARDWARE AND FILL ALL OF THE NAIL HOLES. | |
10/12/1999 | BUILDING - FINAL | Not ready for Inspection | NOT READY FOR INSPECTION | |
09/20/1999 | BUILDING - FINAL | Correction Required | ADDTL COMMS - ALL RAFTERS MUST BE CLIPPED WITH H 2.5. HEADERS NEED HANGERS. NAILS MISSING AT H 2.5. | |
09/20/1999 | BUILDING - FINAL | Denied | IVRS - Inspection 0999* |