Inspection Status: Correction Required
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/12/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - NAIL FASCIA TO EVERY RAFTER, COVER PLYWOOD EDGES WITH METAL TRIM, PROVIDE JOIST HANGERS (4) AT SKYLIGHT HEADERS, NAIL THE TWO 2 X 8S AT THE HIP WITH 16D NAILS STAGGERED AT 16 C.C., NAIL THE SLANTED JOIST HANGERS AT THE HIP. CHECK ALL OF THE HARDWARE AND FILL ALL OF THE NAIL HOLES. |
| 10/12/1999 |
BUILDING - FINAL |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 09/20/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - ALL RAFTERS MUST BE CLIPPED WITH H 2.5. HEADERS NEED HANGERS. NAILS MISSING AT H 2.5. |
| 09/20/1999 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* |