Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - FINAL
Permit Number - T99BU01735
Inspection Description - GRADING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2006 | GRADING - FINAL | Approved | Project is approved | |
09/03/2002 | GRADING - FINAL | Denied | AS PREVIOUSLY NOTED COMPLETE ALL OF THE DRAINAGE ASPECTS ON THIS SITE BEFORE REQUESTING A REINSPECTION. THE BASINS HAVE NOT BEEN CONSTRUCTED PER THE APPROVED PLANS. INLETS AND OUTLETS HAVE NOT BEEN COMPLETED PER THE APPROVED PLANS OR THEY HAVE BEEN DELETED. BOLLARDS HAVE NOT BEEN INSTALLED AT THE INLETS TO PREVENT ACCESS. REMOVE ALL TRASH, DEBRIS, SILT, AND CLAYS FROM WITHIN THE BASINS TO ENSURE PROPER PERCULATION. COMPLETE ALL PEDESTRIAN ACCESS AREAS, THIS WILL INCLUDE ALL WHEELCHAIR ACCESS RAMPS, MARKED CROSSWALKS. THIS IS ONLY A PARTIAL LIST OF THE PROBLEMS THAT REMAIN ON THIS SITE, ONCE THE DRAINAGE WORK HAS BEEN COMPLETED THIS SITE WILL BE REINSPECTED AND A PUNCHLIST WILL BE GENERATED. RELEASE OF THE BONDS FOR THIS SITE WILL NOT BE DONE UNTIL 99 PERCENT OF THIS SITE IS BUILT OUT. ONLY 22 LOTS OUT OF 187 HAVE BEEN COMPLETED AT THIS TIME. | |
09/12/2001 | GRADING - FINAL | Denied | ALL DRAINAGE ITEMS NEED TO BE COMPLETED AND WORK 99% COMPLETE BEFORE RELEASE. |