Inspection Status: Correction Required
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/16/2000 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - APPROVED AS NOTED: 1. FIX THE SHINERS (NAILS THAT MISSED THE RAFTER). ONE METHOD IS TO KNOCK THEM UP SO THAT YOU CAN FIND THEM ON TOP. THEN DRIVE A NAIL INTO THE RAFTER AND PULL THE SHINER. 2. PLEASE CHECK THE EXISTING PLYWOOD. THE EXISTING RAFTER TAILS HAVE BEEN REMOVED AND IT LOOKS LIKE THE EXISTING PLYWOOD IS NOT TIGHT AGAINST THE NEW RAFTERS. PLEASE CHECK THE NAILING. |
| 12/23/1999 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |