Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T98CM05701
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/29/1999 | FRAMING | Correction Required | ADDTL COMMS - WASTE TEST DONE BY J RIVA | |
01/27/1999 | FRAMING | Correction Required | ADDTL COMMS - 1. BANDED MISSION COUPLING REQUIRED OR RIGID COUPLING AT 2ND FLOOR STACK FOR PLUMBING. 2. EXHAUST FAN 3 DUCTS MUST EXHAUST THROUGH 3 HOLE NOT 2. 3. FLOOR TRUSSES REQUIRED TIES 2 FEET FROM EACH END PER 7/SD3. 4. SECOND FLOOR INTERIOR SHEAR WALLS MUST BE FRAMED WITH STUDS 16 O.C. 5. PORCH DECK LEDGER NOT CLIPPED PER 8/SD2. 6. WATER HEATER VENT MUST EXTEND 1 BELOW DRYWALL. 7. SMALL GAS LEAK LOST 1/2 PSI IN 30 MIN. 8. ATTIC ACCESS OBSTUCTED. | |
01/27/1999 | FRAMING | Denied | IVRS - Inspection 0999* |