Permit: T98CM05701

Parcel: 141135610


Addresses:

7353 S GIACHERY AV


Inspection Status: Correction Required

Inspection History: FRAMING

Permit Number - T98CM05701

Inspection Description - FRAMING

Inspection Status - Correction Required

Date Description Inspector Results Comments
01/29/1999 FRAMING Correction Required ADDTL COMMS - WASTE TEST DONE BY J RIVA
01/27/1999 FRAMING Correction Required ADDTL COMMS - 1. BANDED MISSION COUPLING REQUIRED OR RIGID COUPLING AT 2ND FLOOR STACK FOR PLUMBING. 2. EXHAUST FAN 3 DUCTS MUST EXHAUST THROUGH 3 HOLE NOT 2. 3. FLOOR TRUSSES REQUIRED TIES 2 FEET FROM EACH END PER 7/SD3. 4. SECOND FLOOR INTERIOR SHEAR WALLS MUST BE FRAMED WITH STUDS 16 O.C. 5. PORCH DECK LEDGER NOT CLIPPED PER 8/SD2. 6. WATER HEATER VENT MUST EXTEND 1 BELOW DRYWALL. 7. SMALL GAS LEAK LOST 1/2 PSI IN 30 MIN. 8. ATTIC ACCESS OBSTUCTED.
01/27/1999 FRAMING Denied IVRS - Inspection 0999*