Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/29/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - WASTE TEST DONE BY J RIVA |
| 01/27/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. BANDED MISSION COUPLING REQUIRED OR RIGID COUPLING AT 2ND FLOOR STACK FOR PLUMBING. 2. EXHAUST FAN 3 DUCTS MUST EXHAUST THROUGH 3 HOLE NOT 2. 3. FLOOR TRUSSES REQUIRED TIES 2 FEET FROM EACH END PER 7/SD3. 4. SECOND FLOOR INTERIOR SHEAR WALLS MUST BE FRAMED WITH STUDS 16 O.C. 5. PORCH DECK LEDGER NOT CLIPPED PER 8/SD2. 6. WATER HEATER VENT MUST EXTEND 1 BELOW DRYWALL. 7. SMALL GAS LEAK LOST 1/2 PSI IN 30 MIN. 8. ATTIC ACCESS OBSTUCTED. |
| 01/27/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |