Inspection Status: Correction Required

Inspection History: FRAMING

Permit Number - T98CM05609

Inspection Description - FRAMING

Inspection Status - Correction Required

Date Description Inspector Results Comments
02/03/1999 FRAMING Correction Required ADDTL COMMS - I UNDERSTAND PER ENGINEERING 1. NEED BOLTING REQUIRED FOR H.D 2. ALTERNATE H.DOWN P.A TO ALTERNATE. 3. APPROVED SHEAR DETAIL 4. ALSO PLAN CALLS FOR 1/2 ROD BRACE * 4 PLACES
02/03/1999 FRAMING Not ready for Inspection IVRS - Inspection 0000*
02/01/1999 FRAMING Correction Required ADDTL COMMS - 1. LAUNDRY WALL, VENT PIPE AND DRYER DUCT, STICKING OUT OF WALL. 2. NEED WIRE PROTECTION SOUTH BATHROOM WALL BATHROOM TO BEDROOM. 3. NEED SHEAR WALL DETAILS. 4. IF X BRACE IS OKAY IN LIEU OF O.S.B ALSO H.DS NOT INSTALLED NEED PROPER PLAN ON SITE. 5. NEED THE SHEAR WALL OR X BRACE LAYOUT. 6. NEED THE STAND OFF BRACKETS FOR F/PLACE PUT BACK ON THE UNIT.
02/01/1999 FRAMING Not ready for Inspection IVRS - Inspection 0000*
12/23/1998 FRAMING Correction Required ADDTL COMMS - 1. NEED ONE SIMPSON HD6A AT LEFT SIDE 8050 IN LIVING ROOM. 2. NEED 3 SIMPSON RD2A AT RIGHT SIDE OF GARAGE ENT. PERIMITER PLATE ANCHORED WITH DRILL PINS AT 2 0 CENTERS
12/23/1998 FRAMING Partial Approval IVRS - Inspection 0000*