Permit: T98CM05559

Parcel: 103182660

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T98CM05559

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Correction Required

Date Description Inspector Results Comments
03/11/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - NOTE: 2 HOLD DOWNS AT BACK OF HOUSE, WILL CHECK REVISIONS AT INTERMEDIATES. OKAY TO COVER WOOD.
03/08/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. 3 BOLTS ARE ONLY THROUGH 1/2 O.S.B AND/ OR SPLITING BLOCKS. 2. WAITING FOR REVISIONS CONCERING HDS AT BACK OF HOUSE. 3. SEE NOTES 3/4/99 RSA.
03/08/1999 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*
03/04/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - OKAY TO DRY IN ROOF. 1. EXT CLIP DENIED UNTIL PLANS HAVE BEEN REVISED. 2. BOLTS LOOSE AT PATIO POST SUPPORTS. 3. BOLTS MISSING AT LEDGER (PATIO), A35S AT LEDGER (PATIO). 4. PLEASE PUT PATIO REVISIONS IN PACKET FOR EXTERIOR INSPECTS.
03/04/1999 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*