Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/31/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. MISSING H2.5 ON X BRACING DETAIL 3/A8. 2. STILL HAVE NOT COMPLIED WITH ITEM 5 FROM LAST INSPECTION DETAIL 11/A-8. |
| 12/31/1998 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 12/29/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - ITMES 1,3,5 AND 6 FROM 12/18/98 NOT COMPLIED WITH |
| 12/29/1998 |
FRAMING |
|
Denied |
IVRS - Inspection 0160* |
| 12/18/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. GIRDER TRUSS MUST BEAR ON DOUBLE 2X STUDS. 3. RED HEADS LOOSE. 4. AC CONDENSATE BROKEN. 5. COMPLY WITH 11/A8 SHEAR WALL 3. 6. SILL PLATES REQUIRE A MINIMUM OF 2 ANCHOR BOLTS. 7. NO PRESSURE TEST ON PLUMBING. 8. DRYER VENT MUST EXHAUST OUTSIDE. 9. RANGE HOOD MISSING STUD. 10. FIRE BLOCK KITCHEN COLUMNS. 11. W/C FLOOR FLANGE NOT INSTALLED. 12 12. BATH MISSING STUD. 13. COMPLY WITH 6/A8 SOUTH WEST 2. 14. 2X6 SHEAR WALL 1 REQUIRES 16D NAILS AT 7 O.C. MAX ALSO TOP AND BOTTOM PLATES. MUST HAVE DRYWALL SHEAR BEHIND TUB. |
| 12/18/1998 |
FRAMING |
|
Denied |
IVRS - Inspection 0160* |