Permit: T98CM04974

Parcel: 141184710

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
12/31/1998 FRAMING Correction Required ADDTL COMMS - 1. MISSING H2.5 ON X BRACING DETAIL 3/A8. 2. STILL HAVE NOT COMPLIED WITH ITEM 5 FROM LAST INSPECTION DETAIL 11/A-8.
12/31/1998 FRAMING Denied IVRS - Inspection 0999*
12/29/1998 FRAMING Correction Required ADDTL COMMS - ITMES 1,3,5 AND 6 FROM 12/18/98 NOT COMPLIED WITH
12/29/1998 FRAMING Denied IVRS - Inspection 0160*
12/18/1998 FRAMING Correction Required ADDTL COMMS - 1. GIRDER TRUSS MUST BEAR ON DOUBLE 2X STUDS. 3. RED HEADS LOOSE. 4. AC CONDENSATE BROKEN. 5. COMPLY WITH 11/A8 SHEAR WALL 3. 6. SILL PLATES REQUIRE A MINIMUM OF 2 ANCHOR BOLTS. 7. NO PRESSURE TEST ON PLUMBING. 8. DRYER VENT MUST EXHAUST OUTSIDE. 9. RANGE HOOD MISSING STUD. 10. FIRE BLOCK KITCHEN COLUMNS. 11. W/C FLOOR FLANGE NOT INSTALLED. 12 12. BATH MISSING STUD. 13. COMPLY WITH 6/A8 SOUTH WEST 2. 14. 2X6 SHEAR WALL 1 REQUIRES 16D NAILS AT 7 O.C. MAX ALSO TOP AND BOTTOM PLATES. MUST HAVE DRYWALL SHEAR BEHIND TUB.
12/18/1998 FRAMING Denied IVRS - Inspection 0160*