Permit: T98CM04897

Parcel: 133153310

Inspection Status: Correction Required

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/27/2000 PLUMBING - FINAL Correction Required ADDTL COMMS - PLDG FINAL OK OK FOR C OF O NOTE: DO NOT USE ORIGINAL SPRAYERS FOR DOG TUBS. MUST HAVE APPROVED SPRAYER W/BACKFLOW PREVENTION DEVICE. SUPERINTENDENT HAS THEM ON ORDER AND SAID THEY WILL ARRIVE IN 7-DAYS PLEASE NOTIFY ME WHEN THEY HAVE BEEN INSTALLED FOR COURTEST INSPECTION
06/22/2000 PLUMBING - FINAL Correction Required ADDTL COMMS - 1. MUST HAVE HANGER OF STRAP FOR EXPANSION TANK AT WATER HTR 2. SEE NOTE #1 AS REQUESTED 3. MUST HAVE AGA APPROVED GAS SHUT OFF VALVE BEFORE UNION WHRE NEW GAS LINE CONNECTS TO EXSISTING GAS LINE 4. MUST HAVE VACUMN BREAKERS ON ALL SPRAY HOSES FOR DOG TUBS 5. HOSE BIB BY WATER HTR ROOM MUST HAVE VACUMN BREAKER
03/07/2000 PLUMBING - FINAL Correction Required ADDTL COMMS - 1. GAS SHUT OFF VALVES MUST BE INSTALLED WITHIN 3 OF REGULATOR @ WATER HTR AND SUSPENDED HTR IN KENNEL 2. NEED VACUMN BREAKERS ON ALL HOSE BIBS AND ON FAUCET IN DOG TUBS. 3. MUST CAULK ALL FIXTURES 4. THERE IS NO EXPANSION TANK @ WATER HTR. 5. MUST PROTECT EXPOSED ABS WITH VINYL BASE PAINT. 6. NO TRAP PRIMERS WERE INSTALLED AS PER PLAN A LETTER FROM THE ENGINEER STATING THEY DO NOT WANT THE TRAP PRIMERS IS ACCEPTABLE PRIOR TO FINAL. 7. TAIL PC @ DOG TUB CAN BE 24 MAX.
03/07/2000 PLUMBING - FINAL Denied IVRS - Inspection 0000*