Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/17/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. GAS LINE OVER 3 AT FURNACE. 2. TRUSS AT FURNACE AREA, NEEDS A STRINGER. CHECK AT FINAL |
| 12/16/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. 15 CLEARANCE REQUIRED OF CENTRAL WATER CLOSET FLOOR FLANGE TO TUB ONLY 13 1/2 EXISTS. 2. SHIM BETWEEN DOUBLE TOP PLATE AND HEADER AT LIVING ROOM 6050. 3. HEADER AT CLOSET BY GARAGE MUST BEAR ON TRIMMERS SHIM. 4. RED HEADS LOOSE THROUGHOUT. 5. GAS PRESSURE DROPPED 1/2 PSI IN 15 MINUTES. |
| 12/16/1998 |
FRAMING |
|
Denied |
IVRS - Inspection 0160* |