Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/18/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. FIRE WALK BEHIND FURNACE TO BE 2 O.C. WITH NAILING AT PERIMETERS. 2. SECURE AND BLOCK ALL MECH VENTS. 3. MOVE AND SECURE WIRES, H2L LINE 6 AWAY FROM FLUE. 4. H.D.S NOT TIGHT. 5. NEED 110 OUTLET FOR RANGE. 6. SUPPORT 4 GANG SWITCH BOX BEDROOM. 7. MISSING 2ND OUTLET OF DBL. LAV MASTER BATH. |
| 12/18/1998 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |