Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/12/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. A CITY OF TUCSON APPROVAL STAMP MUST BE ON ARCHITECT REPAIR DOCUMENT FOR POXY HOLD DOWN, HOLD DOWN IS INSTALLED PER DOCUMENT DATED 1-6-99 PROCEED AT YOUR OWN RISK. |
| 01/12/1999 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 01/11/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - HOLD DOWN REPAIR NOT MADE |
| 01/11/1999 |
FRAMING |
|
Denied |
DENIED |
| 01/06/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. NEED HOLD DOWN APPROVAL AT GARAGE ENTRY |
| 01/06/1999 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 12/30/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. INTERIOR HOLD DOWNS REQUIRE HD2A WITH EPOXY SPECIAL INSPECTION ANCHOR BOLTS METAL PRODUCTS WAM WITH RED HEAD INSTALLED. PROVIDE ARCHITECT OF RECORD AND C.O.T. APPROVED REPAIR. |
| 12/30/1998 |
FRAMING |
|
Denied |
IVRS - Inspection 0160* |
| 12/29/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. ITEMS 2 AND 8 FROM 12/23/98 OPEN. 2. REPLACE BROKEN ELECTRIC BOX. |
| 12/29/1998 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 12/28/1998 |
FRAMING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 12/23/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. GAS LINE LARGER THAN 3/4 MUST BE SUPPORTED AT 10 O.C. MAX. 2. INTERIOR HOLD DOWNS REQUIRE HD2AS WITH SPECIAL INSPECTION EPOXY BOLTS. 3. SHEAR WALL 8 NOT NAILED ABOVE 8 FEET. 4. PAGE A8 MISSING FROM PLAN. 5. INTERIOR HOLD DOWNS IN WRONG LOCATION BY GARAGE DOORS. 6. STUD CUT AT SW 8. 7. SUPPORT ELBOW FOR 2 VENT BATH. 8. RANGE HOOD CANNOT BE ON GFCI CIRCUIT. 9. NAIL PROTECT 2 WASE VENT MASTER BATH. 10. SECURE BEDROOM WALL TOP PLATE. 11. INADIQUATE RETURN AIR AT CHASE. |
| 12/23/1998 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 12/21/1998 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |