Permit: T98CM04483

Parcel: 137335830

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
04/21/1999 FRAMING Correction Required ADDTL COMMS - 1. CONFIRM ARCHITECTS APPROVAL OF PLATE HARDWARE. 2. REPAIR DAMAGED BLOCKING. 3. FIRE STOP TOP OF TRIANGULAR CHASES. 4. SHEAR BLOCKS APPEAR TO HAVE BEEN RELOCATED FOR 2 DRAIN IN 1ST FLOOR NORTH WEST UNIT. 5. COMPLETE DROPS AND FIRE BLOCKS. 6. HAVE TRUSS MANUFACTURER STAMP THEIR NAME ON EACH TRUSS. 7. REPAIR CUT 2X6 STUD AT 3 VENT, 2ND FLOOR, S.W UNIT. 8. CONFIRM 2ND FLOOR, BOTTOM PLATE NAILING.
04/16/1999 FRAMING Not ready for Inspection IVRS - Inspection 0000*