Permit: T98CM04460

Parcel: 13821019A


Addresses:

127 W CORONA RD

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
03/07/2000 FRAMING Correction Required ADDTL COMMS - DENIED - 1. THE HOUSE IS NOT BUILT PER PLAN. THE MASTER BEDROOM AND BEDROOM #2 HAVE BEEN CHANGED. MASTER BEDROOM IS NOT 185 SQ.FT. ONLY 16 SQ.FT. OF WINDOW. REVISE PLAN AND HAVE APPROVED BY THE CITY OF TUCSON. 2. NEED GAS PRESSURE TEST. ALL ELSE IS OKAY. NEED 10 PSI MINIMUM. 3. OKAY TO INSULATE AND DRYWALL ALL BUT THE MASTER BEDROOM AT YOUR OWN RISK.
03/07/2000 FRAMING Denied IVRS - Inspection 0999*
02/25/2000 FRAMING Correction Required ADDTL COMMS - DENIED - STOPPED INSPECTION. 1. PROVIDE FIRE BLOCKING AT ALL FURR DOWNS. 2. REMOVE PEX 12 MINIMUM FROM LIGHT CANISTERS. 3. SECURE EXHAUST VENT DUCT TO TOP CORD OF TRUSS. 4. PROTECT ELECTRICAL WIRES THROUGHOUT. 5. PROVIDE AN AIR TEST AT WATER LINES.
02/25/2000 FRAMING Denied DENIED
02/17/2000 FRAMING Correction Required ADDTL COMMS - DENIED 1. MECHANICAL IS NOT AS PER PLAN. DIFFERENT SIZE DUCT. 2. NEED TEMPERATURE AND PRESSURE LINE FOR WATER HEATER. RUN IN COPPER TO OUTSIDE. 3. NEED FIRE BLOCKING. 4. REVISE ELECTRICAL PLAN TO SHOW EXISTING. 5. FINISH BOTTOM PLATE BEHIND SHOWER.
02/17/2000 FRAMING Denied IVRS - Inspection 0999*
02/03/2000 FRAMING Correction Required ADDTL COMMS - 1. NEED TO FINISH FRAMING ON MECHANICAL. 2. NEED TO HAVE ELECTRICAL INSTALLED. 3. NEED TO FINISH FRAMING ON PLUMBING PIPE. 4. NOT READY FOR INSPECTION. 5. CALL WHEN READY WITH ALL INTERMEDIATES.
02/03/2000 FRAMING Denied IVRS - Inspection 0999*
10/26/1999 FRAMING Correction Required ADDTL COMMS - 1. BUILDING PRE-SLAB WAS NOT APPROVED ACCORDING TO PAPERWORK ON JOB SITE. 2. FIRE STOP MISSING AT FURNACE OUT ALONG MASONRY TO PROTECT RAFTERS. MUST GET BUILDING PRE-SLAB APPROVED.
10/26/1999 FRAMING Denied IVRS - Inspection 0999*