Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/07/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED - 1. THE HOUSE IS NOT BUILT PER PLAN. THE MASTER BEDROOM AND BEDROOM #2 HAVE BEEN CHANGED. MASTER BEDROOM IS NOT 185 SQ.FT. ONLY 16 SQ.FT. OF WINDOW. REVISE PLAN AND HAVE APPROVED BY THE CITY OF TUCSON. 2. NEED GAS PRESSURE TEST. ALL ELSE IS OKAY. NEED 10 PSI MINIMUM. 3. OKAY TO INSULATE AND DRYWALL ALL BUT THE MASTER BEDROOM AT YOUR OWN RISK. |
| 03/07/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 02/25/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED - STOPPED INSPECTION. 1. PROVIDE FIRE BLOCKING AT ALL FURR DOWNS. 2. REMOVE PEX 12 MINIMUM FROM LIGHT CANISTERS. 3. SECURE EXHAUST VENT DUCT TO TOP CORD OF TRUSS. 4. PROTECT ELECTRICAL WIRES THROUGHOUT. 5. PROVIDE AN AIR TEST AT WATER LINES. |
| 02/25/2000 |
FRAMING |
|
Denied |
DENIED |
| 02/17/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED 1. MECHANICAL IS NOT AS PER PLAN. DIFFERENT SIZE DUCT. 2. NEED TEMPERATURE AND PRESSURE LINE FOR WATER HEATER. RUN IN COPPER TO OUTSIDE. 3. NEED FIRE BLOCKING. 4. REVISE ELECTRICAL PLAN TO SHOW EXISTING. 5. FINISH BOTTOM PLATE BEHIND SHOWER. |
| 02/17/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 02/03/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. NEED TO FINISH FRAMING ON MECHANICAL. 2. NEED TO HAVE ELECTRICAL INSTALLED. 3. NEED TO FINISH FRAMING ON PLUMBING PIPE. 4. NOT READY FOR INSPECTION. 5. CALL WHEN READY WITH ALL INTERMEDIATES. |
| 02/03/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 10/26/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. BUILDING PRE-SLAB WAS NOT APPROVED ACCORDING TO PAPERWORK ON JOB SITE. 2. FIRE STOP MISSING AT FURNACE OUT ALONG MASONRY TO PROTECT RAFTERS. MUST GET BUILDING PRE-SLAB APPROVED. |
| 10/26/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |