Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T98CM04445
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/04/1999 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - STRAP GABLE END TRUSS AT REAR OF HOUSE TO GLU-LAM BEAM - RECALL WHEN READY - SEE PREVIOUS INSPECTION #1 | |
01/04/1999 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000* | |
12/30/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0925* | |
12/29/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - SEE PREVIOUS INSPECTION. | |
12/29/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* | |
12/23/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. STRAP END OF GABLE TRUSSES FRON TAND REAR TO WALL OR BEDROOM BELOW. 2. BLOCK OSB SHEATHING (SHEAR) AT 8 AND CONTINUE OSB SHEAR TO DOUBLE TOP PLATE AT REAR PORCH. 3. STRAP GLU LAM BM AT REAR PORCH HORIZONTALLY TO TOP PLATES. CHECK ALL CLIPS AND SHEAR WALL STUDS AND NAILING AT 16 O.C. . STOPPED INSPECTION. | |
12/23/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* |