Permit: T98CM04445

Parcel: 103181430

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T98CM04445

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Correction Required

Date Description Inspector Results Comments
01/04/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - STRAP GABLE END TRUSS AT REAR OF HOUSE TO GLU-LAM BEAM - RECALL WHEN READY - SEE PREVIOUS INSPECTION #1
01/04/1999 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*
12/30/1998 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0925*
12/29/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - SEE PREVIOUS INSPECTION.
12/29/1998 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*
12/23/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. STRAP END OF GABLE TRUSSES FRON TAND REAR TO WALL OR BEDROOM BELOW. 2. BLOCK OSB SHEATHING (SHEAR) AT 8 AND CONTINUE OSB SHEAR TO DOUBLE TOP PLATE AT REAR PORCH. 3. STRAP GLU LAM BM AT REAR PORCH HORIZONTALLY TO TOP PLATES. CHECK ALL CLIPS AND SHEAR WALL STUDS AND NAILING AT 16 O.C. . STOPPED INSPECTION.
12/23/1998 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*