Inspection History Details
Inspection Status: Denied
Inspection History: FRAMING
Permit Number - T98CM04427
Inspection Description - FRAMING
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/04/1999 | FRAMING | Denied | IVRS - Inspection 0160* | |
12/30/1998 | FRAMING | Denied | IVRS - Inspection 0160* | |
12/24/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. NO PLANS, PERMITS OR PRIOR INSPECTION REPORTS ON SITE. | |
12/24/1998 | FRAMING | Denied | IVRS - Inspection 0160* | |
12/21/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. ITEMS 1,2,3,4 OF 12-19-98 INSPECTION NOT COMPLIED WITH. 2. ALL PRIOR INSPECTION REPORTS MUST BE ON SITE AT ALL INSPECTION. | |
12/21/1998 | FRAMING | Denied | IVRS - Inspection 0160* | |
12/17/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. HOLD DOWNS ARE NOT PER PLAN. 2. SPECIAL INSPECTION REQUIRED ON EPOXY HOLD DOWN. 3. PRIOR INSPECTION REPORTS NOT ON SITE. ALL PRIOR INSPECTION REPORTS ARE REQUUIRED ON SITE. AT EVERY INSPECTION. | |
12/17/1998 | FRAMING | Denied | IVRS - Inspection 0935* | |
12/14/1998 | FRAMING | Denied | IVRS - Inspection 0999* | |
12/09/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. INCORRECT HOLD DOWNS AT INTERIOR LOCATIONS, PLANS CALL FOR HD5AS, HTT22S INSTALLED. 2. INCORRECT HOLD DOWNS AND ANCHOR BOLTS INSTALLED FOR MIS-LOCATED PAHD 42S AT FRONT OF HOUSE, HAVE ARCHITECT OF RECORD SPECIFY CORRECT HOLD DOWN AND BOLT. 3. PROVIDE MANUFACTURS TRUSS DRAWINGS TRUSSES OVER GARAGE NOT BRACED. 4. SHEAR WALL 5 AND 6 AT GARAGE IS BROKEN AT 8 FOOT LINE BY DOUBLE TOP PLATE. PROVIDE ENGINEER ARCHITECT DETIAL FOR SHEAR TRANSFER. 5. COMBUSTABLE MATERIAL WITHIN 1 OF FURNACE VENT. 6. INTERIOR NON BEARING WALLS CANNOT BE IN CONTACT WITH SCISSOR TRUSSES. 7. INADIQUATE SIDE CLEARANCE TO CENTRAL WATER CLOSET 15 TO FINISH WALL REQUIRED. 8. SUPPORT 4 SW BOX TWO ENDS. 9. NO PRESSURE TEST ON PLUMBING. 10. NO WINDOWS. | |
12/09/1998 | FRAMING | Denied | IVRS - Inspection 0999* |