Permit: T98CM04289

Parcel: 11714117A


Addresses:

53 W SIMPSON ST


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T98CM04289

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/27/2000 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
11/01/2000 PLUMBING - INTERMEDIATE Denied OVERHEAD HORIZONTAL PIPING NEEDS TO BE SUPPORTED TO MINIMUM STANDARDS
ISOLATE OVERHEAD COPPER FROM DISSIMILAR METALS
CLOSET FLANGES ARE PART OF INTERMEDIATE INSPECTION
TUBS AND WASTE AND OVERFLOWS ARE PART OF INTERMEDIATE INSPECTOIN
REMEMBER VENTS MUST RISE VERTICALLY TO A POINT NOT LESS THAT 6" ABOVE OVERFLOW BEFORE OFFSETTING HORIZONTALLY
DWV PIPING TO BE WATER TESTED TO 42" AFF
NOTES ONCE YOU CUT PIPE AND INSTALL FITTINGS AND CLEAN OUTS ROUGH IN WATER TEST IS NEGATED
GAS IS SEPARATE INSPECTION
09/22/2000 PLUMBING - INTERMEDIATE Denied 1. NEED APPROVED COPY OF AS BUILT. 2. PROVIDE HISTORY OF PREVIOUS INSPECTIONS.
06/12/2000 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/NO ACCESS
06/08/2000 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*
06/01/2000 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*
05/26/2000 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. NEED APPROVAL ON UNDERGROUND SOIL 2. PLEASE PROVIDE APPROVED REVISED PLANS. NOT INSTALLED AS PER APPROVED PLAN OR INSTALL AS PER APPROVED PLAN
05/26/2000 PLUMBING - INTERMEDIATE Not ready for Inspection NOT READY FOR INSPECTION