Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T98CM04229

Parcel: 133471530

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/05/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. ADDRESS CHANGES TO REAR ELEVATION CHANGES FROM A 6050 WINDOW TO 8050 WINDOW, ELIMINATING 2 OF SHEAR. 2. HAVE REVISIONS MADE TO PLANS OF ANY CHANGES.
11/03/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. USE ALTERNATE HOLD DOWNS MISSING AT REAR SHEAR WALL. 2. NEED TRUSS DRAWINGS. 3. ADD BRACING AS PER DETAIIL 14-D1.
11/03/1998 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*