Permit: T98CM04228

Parcel: 133471430

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/05/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. PROVIDE REVISIONS TO PLAN AND CHANGES TO #5 SHEAR AT THE RAR ELEVATION.
11/03/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. CLIP REAR PATIO POST AND LOCATION OF POST? 2. USE ALTERNATE HOLD DOWN NORTH END OF REAR SHEAR WALL. 3. USE STRAPS AT REAR SHEAR WALL TO GABLE TRUSS. 4. STRAP NON LAPED CORNERS. 5. INADEQUATE EDGE NAILING. DETAIL 13-D1 NO PENETRATION THROUGH 2X BLOCKING, SHOULD BE RAISED TO ROOF SHEATHING. 6. GARAGE HEADER NOT TO PLAN, 2X2212 SHOW REVISIONS TO PLANS THAT ALLOW FLAT TRUSS IN PLACE OF SPECIFIED HEADER. 7. PROVIDE A SET OF APPROVED TRUSS DRAWINGS.
11/03/1998 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*