Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T98CM04162
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/31/1998 | FRAMING | Correction Required | ADDTL COMMS - SAME AS PRIOR INSPECTIONS | |
12/31/1998 | FRAMING | Denied | IVRS - Inspection 0935* | |
12/30/1998 | FRAMING | Denied | IVRS - Inspection 0160* | |
12/24/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. PROVIDE CITY OF TUCSON AND ARCHITECT APPROVED DRAWING FOR HOLD DOWN/ BOLT REPAIR. 2. WRONG EPOXY USED ON HOLD DOWNS EPOXY SET IS REQUIRED EPOXY USED. 3. STUD HOLD DOWN BOLTS LOOSE AT CORNER BY GAS LINE. 4. FIRE BLOCK DROP MISSING CENTRAL BEDROOM. 5. SHEAR WALL 1 IS REQUIRED TO EXTEND FROM FLOOR TO CELING AT TUB IN MASTER BATH PRESENTLY TUB PREVENTS DRY WALL INSTALLATION. | |
12/24/1998 | FRAMING | Denied | IVRS - Inspection 0999* | |
12/23/1998 | FRAMING | Correction Required | ADDTL COMMS - NO PLANS PERMIT OR PRIOR INSPECTION REPORTS ON SITE. REFEE | |
12/23/1998 | FRAMING | Denied | IVRS - Inspection 0935* | |
12/22/1998 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
12/21/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. PROVIDE CITY OF TUCSON AD ARCHITECT APPOROVED DETAIL OF HOLD DOWN BOLT REPAIR. 2. PROVIDE CITY OF TUCSON AND ARCHITECT APPROVED DETAIL OF SHEAR WALL 8 TO TRUSS POSITIVE CONNECTION. 3. PROVIDE EPOXY CONTAINER FOR REPAIRED BOLTS. 4. EPOXY IMPROPERLY MIXED DID NOT SET. 5. P.E.X. CHAFFING ON RELESSED LIGHT BRACKET. 6. FIRE STOP FIRE PLACE CHIMNEY AT CEILING SEAL ALL GAPS. 7. HOLD DOWN BOLTS LOOSE. 8. ANCHOR BOLTS/ RED HEADS LOOSE. 9. ACCESS TO FURNACE BLOCKED, PROVIDE CAT WALK FROM ATTIC ACCESS TO FURNACE. | |
12/21/1998 | FRAMING | Denied | IVRS - Inspection 0999* | |
12/17/1998 | FRAMING | Correction Required | ADDTL COMMS - 1 1. HOLD DOWNS ARE NOT PER PLAN. REVISION MUST BE APPROVED BY CITY OF TUCSON - HD5A HOLD DOWNS REQUIRED. 2. SHEAR WALL 8 REQUIRES NAILING TO STUDS SPACED AT 16 O.C. 3. A POSITIVE SHEAR CONNECTION IS REQUIRED BETWEEN SHEAR WALL 8 AND TRUSSES. PROVIDE CITY OF TUCSON APPROVED DETAIL. 4. SHEAR WALL PANEL EDGES NOT SUPPORTED AND NOT NAILING. 5. P.E.X CHAFFING ON RECESS LIGHT K. 6. FIRE PLACE NOT INSTALLED OR FIRE STOPPED, OFFSET VENT NOT SUPPORTED. 7. INTERIOR WALL CANNOT BE IN CONTACT WITH SCISSOR TRUSS. 8. BLOCK DEFUSERS. | |
12/17/1998 | FRAMING | Denied | DENIED | |
12/16/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. TRUSS H2.5 CLIPS DAMAGED BY IMPROPER NAILING REPLACE ALL THAT ARE NOT NAILED THROUGH MANUFACTURED HOLES. 3. INCORRECT HOLD DOWNS INSTALLED HD5AS REQUIRED INCORRECT ANCHOR BOLTS ALSO. 4. SHEAR WALL 8 REQUIRES EDGE NAILING AT 4 O.C MAX. 5. BLOCK STUB TRUSSES TOP AND BOTTOM. 6. SHEAR WALLS NOT NAILED. | |
12/16/1998 | FRAMING | Denied | IVRS - Inspection 0950* |