Permit: T98CM04162

Parcel: 141136940


Addresses:

7547 S LA PALMA CT


Inspection Status: Correction Required

Inspection History: FRAMING

Permit Number - T98CM04162

Inspection Description - FRAMING

Inspection Status - Correction Required

Date Description Inspector Results Comments
12/31/1998 FRAMING Correction Required ADDTL COMMS - SAME AS PRIOR INSPECTIONS
12/31/1998 FRAMING Denied IVRS - Inspection 0935*
12/30/1998 FRAMING Denied IVRS - Inspection 0160*
12/24/1998 FRAMING Correction Required ADDTL COMMS - 1. PROVIDE CITY OF TUCSON AND ARCHITECT APPROVED DRAWING FOR HOLD DOWN/ BOLT REPAIR. 2. WRONG EPOXY USED ON HOLD DOWNS EPOXY SET IS REQUIRED EPOXY USED. 3. STUD HOLD DOWN BOLTS LOOSE AT CORNER BY GAS LINE. 4. FIRE BLOCK DROP MISSING CENTRAL BEDROOM. 5. SHEAR WALL 1 IS REQUIRED TO EXTEND FROM FLOOR TO CELING AT TUB IN MASTER BATH PRESENTLY TUB PREVENTS DRY WALL INSTALLATION.
12/24/1998 FRAMING Denied IVRS - Inspection 0999*
12/23/1998 FRAMING Correction Required ADDTL COMMS - NO PLANS PERMIT OR PRIOR INSPECTION REPORTS ON SITE. REFEE
12/23/1998 FRAMING Denied IVRS - Inspection 0935*
12/22/1998 FRAMING Not ready for Inspection IVRS - Inspection 0000*
12/21/1998 FRAMING Correction Required ADDTL COMMS - 1. PROVIDE CITY OF TUCSON AD ARCHITECT APPOROVED DETAIL OF HOLD DOWN BOLT REPAIR. 2. PROVIDE CITY OF TUCSON AND ARCHITECT APPROVED DETAIL OF SHEAR WALL 8 TO TRUSS POSITIVE CONNECTION. 3. PROVIDE EPOXY CONTAINER FOR REPAIRED BOLTS. 4. EPOXY IMPROPERLY MIXED DID NOT SET. 5. P.E.X. CHAFFING ON RELESSED LIGHT BRACKET. 6. FIRE STOP FIRE PLACE CHIMNEY AT CEILING SEAL ALL GAPS. 7. HOLD DOWN BOLTS LOOSE. 8. ANCHOR BOLTS/ RED HEADS LOOSE. 9. ACCESS TO FURNACE BLOCKED, PROVIDE CAT WALK FROM ATTIC ACCESS TO FURNACE.
12/21/1998 FRAMING Denied IVRS - Inspection 0999*
12/17/1998 FRAMING Correction Required ADDTL COMMS - 1 1. HOLD DOWNS ARE NOT PER PLAN. REVISION MUST BE APPROVED BY CITY OF TUCSON - HD5A HOLD DOWNS REQUIRED. 2. SHEAR WALL 8 REQUIRES NAILING TO STUDS SPACED AT 16 O.C. 3. A POSITIVE SHEAR CONNECTION IS REQUIRED BETWEEN SHEAR WALL 8 AND TRUSSES. PROVIDE CITY OF TUCSON APPROVED DETAIL. 4. SHEAR WALL PANEL EDGES NOT SUPPORTED AND NOT NAILING. 5. P.E.X CHAFFING ON RECESS LIGHT K. 6. FIRE PLACE NOT INSTALLED OR FIRE STOPPED, OFFSET VENT NOT SUPPORTED. 7. INTERIOR WALL CANNOT BE IN CONTACT WITH SCISSOR TRUSS. 8. BLOCK DEFUSERS.
12/17/1998 FRAMING Denied DENIED
12/16/1998 FRAMING Correction Required ADDTL COMMS - 1. TRUSS H2.5 CLIPS DAMAGED BY IMPROPER NAILING REPLACE ALL THAT ARE NOT NAILED THROUGH MANUFACTURED HOLES. 3. INCORRECT HOLD DOWNS INSTALLED HD5AS REQUIRED INCORRECT ANCHOR BOLTS ALSO. 4. SHEAR WALL 8 REQUIRES EDGE NAILING AT 4 O.C MAX. 5. BLOCK STUB TRUSSES TOP AND BOTTOM. 6. SHEAR WALLS NOT NAILED.
12/16/1998 FRAMING Denied IVRS - Inspection 0950*