Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/06/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - SEE PREVIOUS NOTES |
| 01/06/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 01/05/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. PROVIDE EFFECTIVE DRAFT STOP (FIRE PLACE). 2. PROVIDE MINIMUM 2 CLEARANCE TO FIRE PLACE FLUE. 3. SECURE FIRE BLOCK AT ARCH BY KITCHEN. 4. CAN LIGHTS MINIMUM 1/2 CLEARANCE TO COMBUSTIBLES. 5. STRAP GLB TO TOP PLATES AT BATHROOM HEADER. 6. FIRE BLOCK RANGE HOOD DUCT AREA FURR DOWN. 7. PLACEMENT DOES NOT APPEAR TO ALLOW REMOVABLE OF LARGEST PIECE OF EQUIPMENT. 8. STOPPED INSPECTION |
| 01/05/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 12/31/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - COULDNT LOCATE PLANS |
| 12/31/1998 |
FRAMING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |