Permit: T98CM04137

Parcel: 133477320

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
01/06/1999 FRAMING Correction Required ADDTL COMMS - SEE PREVIOUS NOTES
01/06/1999 FRAMING Denied IVRS - Inspection 0999*
01/05/1999 FRAMING Correction Required ADDTL COMMS - 1. PROVIDE EFFECTIVE DRAFT STOP (FIRE PLACE). 2. PROVIDE MINIMUM 2 CLEARANCE TO FIRE PLACE FLUE. 3. SECURE FIRE BLOCK AT ARCH BY KITCHEN. 4. CAN LIGHTS MINIMUM 1/2 CLEARANCE TO COMBUSTIBLES. 5. STRAP GLB TO TOP PLATES AT BATHROOM HEADER. 6. FIRE BLOCK RANGE HOOD DUCT AREA FURR DOWN. 7. PLACEMENT DOES NOT APPEAR TO ALLOW REMOVABLE OF LARGEST PIECE OF EQUIPMENT. 8. STOPPED INSPECTION
01/05/1999 FRAMING Denied IVRS - Inspection 0999*
12/31/1998 FRAMING Correction Required ADDTL COMMS - COULDNT LOCATE PLANS
12/31/1998 FRAMING Not ready for Inspection NOT READY FOR INSPECTION