Inspection Status: Correction Required
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 05/05/1999 |
ELECTRIC - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. INSTALL BANG PLATES FOR WIRES WITHIN 5/8 FROM EDGE OF STUD. 2. INSTALL ROMEX CLAMP AT FIXTURE SUPPORTS. 3. SEE NOTES ON PREVIOUS INSPECTION # 3,4,7, & 8. 4. CONNECT ALL GROUNDS IN BOXES. 5. TERMINATE CIRCUIT TO COOLER ABOVE IN ELEC BOX. 6. MISSING OUTLET ON BEDROOM WALL NEXT TO FURNACE ROOM, LABELED #3 ON PLANS. 7. STOPPED INSPECTION. |
| 05/05/1999 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999* |
| 04/20/1999 |
ELECTRIC - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. LIGHTS ON KITCHEN APPLIANCE CIRCUITS NOT ALLOWED. 3. SECURE ALL ELECTRIC WIRES WITHIN 8 OF J BOX. 4. LOOSE WIRES THROUGOUT, TERMINATE ALL WIRES J BOX. 5. NUMBEROUS WIRES TOO SHORT TO BE SECURED. 6. 14-2 WIRE NOT ALLOWED FOR APPLIANCE CIRCUIT. 7. FRONT EXT GFI RECEP MISSING. 8. GROUND FAN BOXES, USE PROPER SCREWS TO SECURE BOXES. 8. GROUND FAN BOXES, USE PROPER SCREWS TO SECURE BOXES. -INSPECTION STOPPED- |
| 04/20/1999 |
ELECTRIC - INTERMEDIATE |
|
Denied |
DENIED |