Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T98CM04098

Parcel: 11807002G

Inspection Status: Correction Required

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
05/05/1999 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - 1. INSTALL BANG PLATES FOR WIRES WITHIN 5/8 FROM EDGE OF STUD. 2. INSTALL ROMEX CLAMP AT FIXTURE SUPPORTS. 3. SEE NOTES ON PREVIOUS INSPECTION # 3,4,7, & 8. 4. CONNECT ALL GROUNDS IN BOXES. 5. TERMINATE CIRCUIT TO COOLER ABOVE IN ELEC BOX. 6. MISSING OUTLET ON BEDROOM WALL NEXT TO FURNACE ROOM, LABELED #3 ON PLANS. 7. STOPPED INSPECTION.
05/05/1999 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*
04/20/1999 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - 1. LIGHTS ON KITCHEN APPLIANCE CIRCUITS NOT ALLOWED. 3. SECURE ALL ELECTRIC WIRES WITHIN 8 OF J BOX. 4. LOOSE WIRES THROUGOUT, TERMINATE ALL WIRES J BOX. 5. NUMBEROUS WIRES TOO SHORT TO BE SECURED. 6. 14-2 WIRE NOT ALLOWED FOR APPLIANCE CIRCUIT. 7. FRONT EXT GFI RECEP MISSING. 8. GROUND FAN BOXES, USE PROPER SCREWS TO SECURE BOXES. 8. GROUND FAN BOXES, USE PROPER SCREWS TO SECURE BOXES. -INSPECTION STOPPED-
04/20/1999 ELECTRIC - INTERMEDIATE Denied DENIED