Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/02/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. 1/2 CLEARANCE ON ENTRY SHEAR WALL AND SHEAR TRANSFER NEEDED. 2. H1 PAHD 42 OR EQUAL NEED INSIDE NORTH EAST CORNER. 3. K/D3 NOT COMPLYED WITH. |
| 12/01/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. GABLE TIES NOT NAILED S. WALL. 2. SHEAR PANELS NOT NAILED IN REAR OF HOUSE AND NORTH SIDE. 3. CONTINUE METAL TIE FROM PHAD TO 2ND FLOOR BEAM AND TIE HEADER. 4. SHEAR WALL #8 IN FRONT NOT NAILED PROPERLY AND MANY NAILS COUNTER SUNK 1/2 WAY THROUGH. 5. SHEAR TRANSFER AT THIS POINT TO TRUSSES AND INT. SHEAR WALLS. 6. H7 STRAPS MISSING ON INT. SHEAR WALLS. 7. STRINGERS MISSING IN TRUSSES. 8. UPPER FRONT FACING GABLE END NOT STRAPED. 9. SHEAR WALL #7 MISSING NORTH EAST CORNER UPSTAIRS. |
| 12/01/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0145* |