Permit: T98CM04007

Parcel: 116090180

Inspection Status: Correction Required

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/15/1999 BUILDING - FINAL Correction Required ADDTL COMMS - NO GAS-SEPTIC APPROVED BY SEPERATE PERMIT. T98PL01895
12/14/1999 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*
12/13/1999 BUILDING - FINAL Correction Required ADDTL COMMS - SPARK ARRESTOR AT CHIMNEY. FIRE CAULK GAS AT FIREBOX. REMOVE DAMPER. GFIC IN GARAGE WIRED LINE SIDE. MASTER GFCI WIRED INCORRECT. PENNISULA GFCI NOT ISOLATED. EXHAUST VENT & STOVE CANNOT BE ON THIS CIRCUIT. LEAVE PANEL COVER OFF IN GARAGE
12/13/1999 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
12/08/1999 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*