Permit: T98CM03857

Parcel: 141184680

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
10/30/1998 FRAMING Correction Required ADDTL COMMS - 1. NEED FURRING AROUND MASTER BATH TUB, CHECK AT SHEET ROCK NAILING.
10/28/1998 FRAMING Correction Required ADDTL COMMS - 1. GARAGE FIRE SEPARATION SHEAR WALL 3 CANNOT HAVE STUDS SPACED GREATER THAN 16 O.C. 2. BLOCK FURNACE PLATFORM FOR SHEAR WALL NAILING. 3. DOUBLE TOP PLATES OF SHEAR WALLS MUST HAVE PROPERLY NAILED FHA STRAPS AT CUTS. 4. LTT20 AT GARAGE ENTRY WRONG LOCATION MUST BE AT JAM. 5. SHEAR WALL 3 AT GARAGE NOT PROPERLY ANCHORED TO FLOOR ALSO SHEAR WALL 2. 6. FIRE STOP COLUMNS AT KITCHEN. 7. STUDS AT BATHROOM SHEAR WALL 1 MUST BE AT 16 O.C. NOT FURRING BLOCK AROUND TUB. 8. ANCHOR BOLTS MISSING AT PATIO DOOR. 9. SHEAR WALL CORNERS OF INTERIOR WALLS REQUIRED NAILES AT 12 O.C. 10. WIRES LOOSE AT MASTER BATH. 11. LAUNDRY PLUMBING OUTSIDE OF WALL. 12. PLUMBING HEADER CUT REPLACE ALL CUT STUDS.
10/28/1998 FRAMING Denied DENIED