Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/15/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. CHECK SHEAR NAILING ON WALL AREA #5 AT BACK TUB AREA ON SHEET ROCK NAILING. |
| 10/14/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. NO PLANS OR PERMIT OR MANUFACTURS TRUSS DRAWINGS. 2. TRUSSES NOT PROPERLY BRACED. 3. TUB SHEAR BLOCKING MISSING AROUND TUB. 4. NAIL PROTECT SHOWER RISER. |
| 10/14/1998 |
FRAMING |
|
Denied |
DENIED |
| 10/13/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. BLOCK ALL WALL LINES AT SHEAR WALLS |
| 10/13/1998 |
FRAMING |
|
Denied |
DENIED |
| 10/09/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. BLOCK STUB TRUSSES TOP AND BOTTOM. 2. FIRE BLOCK ARCH. 3. INSTALL TRUSS BRACES. 4. NAIL FHA STRAPS. 5. SHEAR BLOCK TUB 6. FURNACE VENT IN CONTACT WITH COMBUSTIBLES. |
| 10/09/1998 |
FRAMING |
|
Denied |
DENIED |