Permit: T98CM03494

Parcel: 116061390

Inspection Status: Correction Required

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
02/17/1999 BUILDING - FINAL Correction Required ADDTL COMMS - 1. ROMEX EXPOSED ON WEST SIDE AND NORTH SIDE. 2. I NEED TO SEE PERMIT FOR UPGRADING OUTSIDE ELECTRIC PANEL.
02/11/1999 BUILDING - FINAL Correction Required ADDTL COMMS - 1. ROMEX CAN NOT BE USED OUTSIDE- EXPOSED. 2. ANTI SIPHON VALUE ON HOSE BIB. 3. WE NEED TO ISOLATE NEUTRAL AND GROUNDS IN THE SUB PANEL WITHIN THE HOUSE- THE HOUSE DOES NOT HAVE GROUNDED RECEPS. 4. GROUNDS ARE NOT TIGHTENED AT BOTH RODS, HOW DO YOU DRIVE 8-0 GROUND RODS UNDER ROOF EAVES? 5. COVER ROMEX AT CORNER OFF ADDITION TO EXISTING. 6. NEED COVERED LIGHT IN CLOSET. 7. MOVE LIGHTS FROM THE GARAGE DOOR AREA.
02/11/1999 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*