Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T98CM03466
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/18/1998 | FRAMING | Correction Required | ADDTL COMMS - SEE #6 AT REAR PORCH JACK RAFTERS FROM PREVIOUS INSPECTION. | |
12/18/1998 | FRAMING | Partial Approval | IVRS - Inspection 0000* | |
11/12/1998 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
11/10/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. 1 CLEARANCE REQUIRED AT WATER HEATER FLUE TO COMBUSTIBLES. 2. SUPPORT 1/2 GAS LINE IN ATTIC AT LIVING ROOM 6 O.C. MAX APART. 3. NO TEST ON GAS LINE. 4. NEED ATTIC VENTALATION IN LIVING AREA. 5. NEED REBISED PLANS. 6. NEED REVISION PLANS ARCHITECT ON JACK RAFTERS TO HIP CONNECTION AT REAR PORCH. | |
11/10/1998 | FRAMING | Not ready for Inspection | NOT READY FOR INSPECTION | |
11/02/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. SCABS AT TRUSS REPAIR ARE 1/2 AWAY FROM BOTTOM CORD OF TRUSS - NOT PER ENGINEERS REPAIR SPECS. 2. NEED CITY AND ARCHITECT APPROVED CHANGE ON FRAMING OF REAR PORCH BEAMS 6X HANGING OFF 6X WITH HANGER NOT IN PLANS. 3. DOUBLE STUD REQUIRED UNDER GIRDER TRUSS IN GARAGE IN SOUTH WALL AND NEED CITY APPROVED REVISION FOR GARAGE, ROOF BEARING ETC. NEED REVISED HEADER AND BEAM PLAN ALSO. | |
11/02/1998 | FRAMING | Denied | IVRS - Inspection 0999* |