Permit: T98CM03293

Parcel: 141195690

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
10/23/1998 FRAMING Correction Required ADDTL COMMS - CHECK STUD INSTALLATION BEHIND HALL BATH VANITY AT SHEET ROCK NAILING
10/21/1998 FRAMING Correction Required ADDTL COMMS - 1. 40B/D-1 NOT COMPLIED WITH AT BEDROOM 3/WALK IN CLOSET WALL. 2. LAUNDRY HOSE BIBS LOOSE. 3. STUD MISSING CENTRAL BATH WALL OVERSPAN. 4. PEX CANNOT BE WITHIN 12 OF RECESSED LIGHTS. 5. FIREPLACE CHIMNEY IN CONTACT WITH COMBUSTIBLES. 6. 45/D1 NOT COMPLIED WITH ALSO CRICKET MISSING. 7. FIREBLOCK MASTER BATH BY A/C LINES.
10/21/1998 FRAMING Denied DENIED