Permit: T98CM03272

Parcel: 141203800

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
09/17/1998 FRAMING Correction Required ADDTL COMMS - 1. RED HEAD ANCHOR BOLTS LOOSE. 2. TRUSSES DO NOT HAVE PROPER BEARING AT FRONT WALL TRUSSES HAVE BEEN CUT AND ONLY 3/4 BY 1 1/2 BEAR ON PLATE. PROVIDE CITY OF TUCSON APPROVED TRUSS ENGINEERING DOCUMENTS AND REPAIR 13 TRUSSES. 3. BATH TUB NOT INSTALLED MASTER BATH. 4. TRUSS SHEAR PANEL HAS 16 HOLE FOR DUCT. PROVIDE CITY OF TUCSON APPROVED ENGINEERING REPAIR. 5. FIRE PLACE FIRE STOP INCORRECTLY INSTALLED ALSO HEADER MISSING. 6. KITCHEN WALL LOOSE.
09/17/1998 FRAMING Denied DENIED
09/16/1998 FRAMING Not ready for Inspection NOT READY FOR INSPECTION