Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/17/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. RED HEAD ANCHOR BOLTS LOOSE. 2. TRUSSES DO NOT HAVE PROPER BEARING AT FRONT WALL TRUSSES HAVE BEEN CUT AND ONLY 3/4 BY 1 1/2 BEAR ON PLATE. PROVIDE CITY OF TUCSON APPROVED TRUSS ENGINEERING DOCUMENTS AND REPAIR 13 TRUSSES. 3. BATH TUB NOT INSTALLED MASTER BATH. 4. TRUSS SHEAR PANEL HAS 16 HOLE FOR DUCT. PROVIDE CITY OF TUCSON APPROVED ENGINEERING REPAIR. 5. FIRE PLACE FIRE STOP INCORRECTLY INSTALLED ALSO HEADER MISSING. 6. KITCHEN WALL LOOSE. |
| 09/17/1998 |
FRAMING |
|
Denied |
DENIED |
| 09/16/1998 |
FRAMING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |